Resolute® Chromatography Columns

Resolute® Chromatography Columns

Resolute columns are ideally suited for process purification in the biopharmaceutical industry. A patented nozzle valve provides all column functions required for packing, unpacking and running of the column in a closed system. Based on established and well proven designs, the Resolute column provides improved column performance and true linear scalability combined with reproducible column packing methods for today’s high performance media.

Pall continues to work closely with the biopharmaceutical manufacturing industry to advance the state of the art for both chromatographic performance and productivity. The packing process is controlled by a slurry packing system which,

combined with a Resolute column, offers a complete solution for process chromatography from development to manufacturing scale. 

Features and Benefits

  • Standard column diameters from 280 mm to 1200 mm – all with selectable bed heights from  100 mm up to 600 mm  
  • Bed Height: fixed or adjustable (200 mm adjustment)
  • Nozzle Valve: choice of manually operated Resolute DM, or pneumatically actuated Resolute DP columns
  • Choice of bed supports in polyethylene or stainless steel
  • Piston seal and precision bore tube eliminates need for additional mechanical compression or pneumatic activation of adjuster seals
  • Compatible with a wide range of Chromatographic Media
Resolute Chromatography Columns

Sanitary Design

Resolute Chromatography Column

 
  • Fully flushed flow path and adjuster seal for clean-in-place (CIP)
  • Minimum dead space fixed cell seal arrangement
  • Reduced risk of corrosion
    • non metallic nozzle flow path for high  salt and low pH conditions
    • forged stainless steel tube eliminates weld seams on tube wall and flanges
  • Visible valve flow path aids detection of entrapped air
  • Sanitary clamp terminations
  • Leachate free acrylic tube — no phthalates
  • Peroxide cured seals — no sulphur containing leachate
  • Process wetted materials meet regulatory requirements

Column Options

Standard Columns

  • Actuated nozzle valve; fits 400 to 1200 mm diameter columns
  • Bed supports:
    • Polyethylene 10/20/60 µm
    • Stainless steel 10/20/50 µm
  • Lockable castors and adjustable feet supplied as standard*
  • Up to 1000 mm diameter only.

Engineered Columns

  • Operating pressure up to 10 bar
  • Columns from 400 mm to 2000 mm diameter
  • Certification to ASME Div VIII sec 1 or PD5500.CE where applicable
  • Service frames for piston end cell maintenance
  • Alternative materials: Hastalloy C22, Stainless Steel 1.4435, 1.4439
  • Hydraulic Actuators — see technical specifications for operating modes

View additional chromatography columns.

Products in this datasheet may be covered by one or more patents including :
EP 1 085 931
US 6,446,679