HDC® II Filter Cartridges for Gas Applications
Pall HDC II all-polypropylene filter cartridges incorporate proprietary HDC II tapered pore polypropylene depth media. The single open-ended (SOE) AB filter cartridge style features a high-area pleated modular element construction designed to fit in sanitary filter housings.
HDC II filter cartridges are well suited for a broad range of fine particle and prefiltration applications where purity, economy and reliability are critical. Typical biopharmaceutical applications include biologicals, pharmaceuticals, fermentation feeds and intermediates, and vaccines.
Features and Benefits
- All-polypropylene construction
- Resin-free, melt-sealed
- Constant density tapered pores
- High-capacity for long-life
- Fixed pore, non-shedding
- Low protein binding
- Low extractables
- Broad chemical compatibilities
- Autoclavable and steamable in situ
- Manufactured for use in conformance with cGMP
- ISO 9000 Certified Quality System
- Pharmaceutical P optimized grades with Certificate of Test provided
- FDA-listed materials per 21 CFR
Note: These filters are also available in Kleenpak Nova capsule format.
Quality and Bio-Safety
Biological Tests
- Meets USP Biological Reactivity Test, in vivo, for Class VI-121 °C Plastics
Effluent Quality Tests*
- Meets Cleanliness per USP Particulates in Injectables
- Non-Fiber-Releasing Non-Pyrogenic per USP
- Bacterial Endotoxins (< 0.25 EU/mL)
- Meets Total Organic Carbon and Water Conductivity per USP Purified Water, pH per USP Sterile Purified Water
* Per lot sample soak or rinse-up flush aliquots.
Operating Limits(1)
Operating Temperature
Maximum Differential Pressure
50 °C
5.5 bard (80 psid)
80 °C (Maximum)
4.1 bard (60 psid)
1 In compatible fluids which do not soften, swell or adversely affect the filter medium or materials of construction Steam Sterilization
|
Operating Temperature |
Maximum Differential Pressure |
| 50 °C | 5.5 bard (80 psid) |
| 80 °C (Maximum) | 4.1 bard (60 psid) |
Maximum Cumulative Steam Sterilization
Steam Sterilizing Temperature of AB Steaming Exposure (In situ or Autoclave)
| 50 hours | Up to 140 °C |
Retention Ratings
| Media Code | Liquid Absolute Rating | Liquid Retention (90%) | Gas Efficiency3 for 0.3 µm Aerosols | Nominal Filter Area4 |
Gas Flow Rates per 254mm Cartridge2 for Air m3/h, P = 10 mbar (0.15 psi)4 |
| J006 | 0.6 µm 3 | < 1.0 µm 3 | 100.00 % | 0.62 m2 (6.67 ft2) | 4 |
| J012 | 1.2 µm | < 1.0 µm 3 | 100.00 % | 0.69 m2 (7.43 ft2) | 10 |
| J025 | 2.5 µm | < 1.0 µm 3 | 99.95 % | 0.86 m2 (9.26 ft2) | 14 |
| J045 | 4.5 µm | 1.2 µm | 99.75 % | 0.86 m2 (9.26 ft2) | 17 |
| J060 | 6.0 µm | 3.0 µm | 99 % | 0.40 m2 (4.31 ft2) | 24 |
| J100 | 10.0 µm | 5.4 µm | 93 % | 0.52 m2 (5.6 ft2) | 39 |
| J200 | 20.0 µm | 10.0 µm | - | 0.53 m2 (5.7 ft2) | - |
| J400 | 40.0 µm | 22.0 µm | - | 0.37 m2 (3.98 ft2) | - |
3 Based on mineral oil test.
4 For 254 mm (10 in.) nominal length cartridge
5 Extrapolated value.