ProfileĀ® II Filter Elements
Available in RF Series, RMF Series and AB Series—Code 3 and Code 7.
Profile® II filters are all polypropylene. The elements have an absolute-rated downstream section, and a continuously graded pore size upstream section, which increases service life many-fold.
The materials of construction - chemically resistant polypropylene – permit application in a very wide range of corrosive and non-corrosive fluids. The fibers in Profile II filters may be considered continuous. No binder resin is used – the fibers are “bonded” by intertwining during the manufacturing process. As a result, Profile II filters show no media migration.
The Profile II filter has numerous applications in a broad range of industries that include chemical, petrochemical, photochemical, pharmaceutical, biological, electronic, magnetic tape, electroplating, food and beverage, cosmetic, veterinary, medical and fermentation industries. They are used as both prefilters and as final filters.
For applications where the filters are heated for any reason above 122°F (50°C) and the temperature is then reduced by 36°F (20°C) or more, AB Series elements are recommended. See Bulletin PRO 400 and PRE-1 for more detailed information.
Table I. Profile II Cartridge Grades And Their Characteristics
| Removal Ratings | Typical Clean Pressure Drop | |||||
|---|---|---|---|---|---|---|
| Liquid Service | Gaseous Service | Liquid Service | Gaseous Service | Typical Aqueous | ||
| Cartridge Grade |
Rating in µm At % Efficiency 99.9% |
100% | DOP (0.3µm)1 Efficiency % |
Aqueous Pressure drop2 |
CFM of air per PSIper 10" cartridge3 |
Flow (GPM/10" Cartridge) |
| 003* | <0.54 | <0.54 | >99.9999 | 3.5 | 2.3 | 1 - 2.5 |
| 005 | <0.54 | <0.54 | >99.9999 | 2.8 | 2.7 | 1 - 2.5 |
| 010 | <0.54 | 1 | >99.9999 | 2.6 | 3.6 | 1 - 3 |
| 030 | 2.5 | 3 | >99.9999 | 1.5 | 6.4 | 2 - 5 |
| 050 | 4 | 5 | >99.9999 | 0.8 | 11.0 | 3 - 8 |
| 070 | 6 | 7 | >99.9999 | 0.5 | 17.0 | 5 - 12 |
| 100 | 9 | 10 | 99.2 | 0.3 | 29.0 | 6 - 15 |
| 120 | 11 | 12 | 96.5 | 0.2 | 36.0 | 6 - 15 |
| 150 | 13 | 15 | 88 | 0.15 | 44.0 | 8 - 15 |
| 200 | 18 | 20 | 84.8 | 0.10 | 75.0 | 10 - 15 |
| 300 | 26 | 30 | 67 | 0.08 | 119.0 | 10 - 15 |
| 400 | 35 | 40 | 48.3 | 0.05 | 207.0 | 10 - 15 |
| 700 | 70 | —5 | 34 | <0.05 | 415.0 | 10 - 15 |
| 900 | 904 | —5 | 25 | <0.05 | 640.0 | 10 - 15 |
| 1200 | 1204 | —5 | 10 | <0.05 | 1000.0 | 10 - 15 |
1 Air flow used for these data was 20 cfm/10" module, except grade 700, which was run at 4 cfm.
2 Pressure drop is PSI per GPM for a single 10" module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.
3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.
4 Extrapolated values.
5 Precise evaluation of the 100% removal efficiency for these coarse grades is not possible with test procedure utilized.
*AB style only.
Sizes
The Profile II RF, and RMF Series filter elements are 21/2" O.D. and are available in one piece 10", 20", 30", and 40" length modules. Profile II elements are also available in 23/4" diameter AB Code 3, 7 and 8 Series configurations. See Bulletin PRO 400 for further details.
| Profile II Element Part Numbers | ||
|---|---|---|
| 100% Removal Rating, µm | For General Application | For General Application Including In- Situ Steam Sterilization,and In-Situ Hot Water Sanitizing1 |
| RF Series | AB Series | |
| 0.3* 2 | — | AB Y003 |
| 0.5 2 | R F005 ![]() |
AB Y005 |
| 1 | R F010 ![]() |
AB Y010 |
| 3 | R F030 ![]() |
AB Y030 |
| 5 | R F050 ![]() |
AB Y050 |
| 7 | R F070 ![]() |
AB Y070 |
| 10 | R F100 ![]() |
|
| 12 | R F120 ![]() |
|
| 15 | R F150 ![]() |
|
| 20 | R F200 ![]() |
|
| 30 | R F300 ![]() |
|
| 40 | R F400 ![]() |
|
| 70 | R F700 ![]() |
|
| 90 | R F900 ![]() |
|
| 120 | R F1200 ![]() |
|
| Gasket | Code |
|---|---|
| None | No Symbol |
| Elastomeric Material** | M*** |
| |
|---|---|
| Nominal Length, In. | Code |
| 10 | 1 |
| 20 | 2 |
| 30 | 3 |
| 40 | 4 |
![]() | |
|---|---|
| Gasket Material | Code |
| Alloy of Polypropylene and Ethylene Propylene Diene Monomer (EPDM) | H21 |
| Application | Code |
|---|---|
| Pharmaceutical | P |
| Other | Omit |
| O-Ring Option | Code |
|---|---|
| Silicone | H4 |
| Viton A | H |
| Ethylene-Propylene | J |
| Cartridge Diameter O.D., In. | Adapter Configuration | Number of O- Rings | O-Ring Size | FDA Listed Materials of Construction | Code |
|---|---|---|---|---|---|
| 2 3/4 | Flat Top | 2 | 222 | Yes | 3 |
| 2 3/4 | Finned Top, Locking Tabs |
2 | 226 | Yes | 7 |
| 2 3/4 | Finned Top | 2 | 222 | Yes | 8 |
1 Only P grade AB Series elements may be in-situ steam sterilized.
2 Extrapolated valves.
* AB style only.
** Provides a positive sealing surface to eliminate potential fluid bypass in competitive housings with blunt knife edges. *** When the M symbol is selected the part number must end in H21 code.
Table III. Housings For Profile II Elements
| Type Of Element | Housing Available |
|---|---|
| R F Series and RM F Series | See Housing Data Sheets H2, H13, H14, H15, H16, H17, H18, H19, H36, H37, H38 and H39 for Pall housings specifically designed toaccommodate these elements. R F Series elements may also be used with competitor built housings which accommodate 21/2" O.D. x 10", 20", 30", and 40" nominal length elements; however,sealing may be marginal for grades 030 (3µm absolute) and finer. |
| AB Y Series, Code 3, 7 and 8 | See Housing Data Sheets H22, H26, H28, H29, H30, H31, H32, and H35. |



Y003 