Air, Aggressive Environments/Aerosol Testing- Environmental QC

Membranes for Aggressive Environments/Aerosol Testing

Pallflex® Air Monitoring Filters




Pallflex Tissuquartz™Binder-free pure quartz offers superior chemical purity. High flow rate and filtration efficiency. Uniquely designed for air monitoring in high temperatures and aggressive atmospheres.

Filter Media: Pure quartz, no binder 
Typical Filter Thickness: 432 µm (17 mils)
Typical Filter Weight: 5.8 mg/cm2
Typical Aerosol Retention (Following ASTM D 2986-95A, 0.3 µm DOP at 32 L/min/100 cm2 filter media: 99.90% 
Typical Air Flow Rate: 73 L/min/cm2 at 0.7 bar (70 kPa, 10 psi)  
Typical Water Flow Rate: 220 mL/min/cm2 at 0.35 bar (35 kPa, 5 psi)
Maximum Operating Temperature: Air 1093 ºC (2000 ºF)  

Pallflex Emfab™Borosilicate microfibers reinforced with woven glass cloth and bonded with PTFE. Flushed with DI water to remove water-soluble residue. Low moisture and low air resistance. Withstands folding for weighing and transport. Preferred filter for ambient air sampling and stack emission testing.

Filter Media: Borosilicate glass microfibers reinforced with woven glass cloth and bonded with PTFE
Typical Filter Thickness: 178 µm (7 mils)
Typical Filter Weight: 5.0 mg/cm2

Typical Aerosol Retention (Following ASTM D 2986-95A, 0.3 µm DOP at 32 L/min/100 cm2 filter media: 99.95%
Typical Air Flow Rate: 68 L/min/cm2 at 0.7 bar (70 kPa, 10 psi)
Typical Water Flow Rate: 220 32 mL/min/cm2 at 0.35 bar (35 kPa, 5 psi)
Maximum Operating Temperature: Air 260 ºC (500 ºF)
 


















Pall Preferred Online Lab Community

Pallflex Fiberfilm™ Unique combination of heat-resistant borosilicate glass fibers and moisture-resistant fluorocarbon. Moisture variations in air or gases will not cause chemical reactions on the filter. Low moisture pickup and low nominal air resistance. Ideal for diesel exhaust sampling.

Filter Media: Heat resistant borosilicate glass fiber coated with fluorocarbon (TFE)
Typical Filter Thickness: 203 µm (8 mils)
Typical Filter Weight: 3.4 mg/cm2
Typical Aerosol Retention (Following ASTM D 2986-95A, 0.3 µm DOP at 32 L/min/100 cm2 filter media: 96.40%
Typical Air Flow Rate: 180 L/min/cm2 at 0.7 bar (70 kPa, 10 psi) 
Typical Water Flow Rate: 220 mL/min/cm2 at 0.35 bar (35 kPa, 5 psi)
Maximum Operating Temperature: Air 315.5 ºC (600 ºF)

Devices and Accessories for Aggressive Environments/Aerosol Testing

47 mm In-line Filter Holders
47 mm In-line Filter Holder, AluminumLightweight, anodized aluminum filter holder.