Profile® II RFN Series Filter Elements
Profile® II RFN Series filters* are composed of an all nylon filter medium with glass filled polypropylene cores as standard. They are also available with glass filled nylon cores. The elements have an absolute rated downstream section, and a continuously profiled pore size upstream section, which increases service life many-fold.
The fibers in Profile II RFN filters are for practical purposes continuous. No binder resin is used —the fibers are “bonded” by intertwining during the manufacturing process. As a result , Profile II RFN filters show no media migration.
Fluid Capability
The materials of construction of the standard RFN Series filters permit application in a very wide range of liquids, and gases. For use with hot vegetable and mineral oils, which cause the polypropylene core to swell, the GN Series, with a glass filled nylon core, is preferred. For use with xylene, toluene or other aromatics, and for high temperatures, the glass filled nylon core is required. The Profile II RFN Series nylon filters should not be used in any oxidizing conditions or with water above 115 °F (40 °C).| Removal Ratings | Clean Pressure Drop | ||||||
Liquid Service |
Gaseous Service | ||||||
| Rating in µm at % Efficiency | |||||||
Cartridge Grade |
90% |
99% |
99.9% |
99.98% |
Aqueous Pressure Drop (psi/gpm)1 |
CFM of Air per PSI per 10 in. Cartridge2 |
Typical Aqueous Flow (GPM/10 in. Cartridge |
| 050 | 2.0 | 3.0 | 4 | 5 | 0.8 | 11 | 3 - 8 |
| 100 | 6.5 | 7.5 | 9 | 10 | 0.3 | 29 | 6 - 15 |
| 200 | 10 | 14 | 18 | 20 | 0.10 | 75 | 10 - 15 |
| 400 | 30 | 30 | 35 | 40 | 0.05 | 207 | 10 - 15 |
| 700 | 32 | 50 | 703 | - | <0.05 | 415 | 10 - 15 |
Operating Characteristics
- Recommended Maximum Pressure Differential for Standard RFN Series Filters: 75 psi up to 30 °C (86 °F), 50 psi up to 70 °C (158 °F), and 35 psi up to 82 °C (180 °F)
- Recommended Maximum Pressure Differential for GN Series Filters with Glass Filled Nylon Cores: 90 psi up to 30 °C (86 °F), 80 psi up to 70 °C (158 °F), 70 psi up to 100 °C (212 °F), and 50 psi up to 150 °C (300 °F)
Sizes
- 2 1/2 in. O.D. and are available in one piece 10 in., 20 in., 30 in., and 40 in. length modules
Housings
- Housings are available in polypropylene, other polymers, carbon steel and stainless steel
1Pressure drop in PSI per GPM for a single 10” module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.
2For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.
3Air flow used for these data was 20 cfm/10 in. module, except grade 700, which was run at 4 cfm.
This information is a guide to the part number structure and possible options. For availability of specific options and housing details, please contact Pall.
Example Part Number: R GY 3 FN 100 (See bold references in tables below)
Part Number: R < Core Code from Table 1 > < Length Code from Table 2 > FN < Removal Rating Code from Table 3 >
Table 1 - Inner Core
| Code | Inner Core Material of Construction |
| GY | Glass Filled Polypropylene (Standard) |
| GN | Glass Filled Nylon (Optional) |
Table 2 - Length
| Code | Nominal Length, Inches |
| 1 | 10 |
| 2 | 20 |
| 3 | 30 |
| 4 | 40 |
Table 3 - Removal Rating
| Code | 100% Removal Rating µm |
| 050 | 5 |
| 100 | 10 |
| 200 | 20 |
| 400 | 40 |
| 700 | 704 |