LMO Spring Seal Series Filter Housings
Self-Adjusting Sealing Device Ensures Positive Filter Cartridge Seal
- Provides positive sealing of non-compressible filters1 such as pleated, carbon, metallic, and membrane cartridges
- Accepts 10.2 cm (4 in.), 25.4 cm (10 in.), 50.8 cm (20 in.), or 76.2 cm (30 in.) DOE filter cartridges2
- O-ring head and shell seal minimizes fluid leakage
- In-line inlet and outlet connections for easy installation
- Cast iron and 316 stainless steel or all 316 stainless steel materials of construction
1 The LMO Spring Seal Series housing is not recommended for metallic cartridges. For metallic cartridges use the LMO Vari-Seal™ housing only.
2 When fitting with 10.2 cm (4 in.) DOE filters, please order filters under Code 550 to assure proper fit.
Housing Specifications
Maximum operating pressure
12.1 bar (175 psig) @ 93 °C (200 °F)
| Construction | Head3 | Shell |
| LMOSS: | Cast iron4 | 316 stainless steel |
| LMOSS S: | Cast 316 stainless steel | 316 stainless steel |
Connections
Inlet/Outlet: 1⁄2 in., 3⁄4 in., or 1 in. NPT
Drain:
LMOSS: Drain plug, 316 stainless steel, 1⁄4 in. NPT
LMOSS S: Drain plug, 316 stainless steel, 1⁄4 in. NPT
| Shell O-rings | Ethylene propylene (standard), nitrile, FEP, fluorocarbon elastomer, neoprene, silicone elastomer | |
| Spring seal O-rings | FEP (standard), ethylene propylene |
Bracket option
Stainless steel brackets are available as a standard option.
T-Handle option
T-handle cover nuts are available in carbon steel or 316 stainless steel. Standard units are supplied with hex head cover nut.
Flange option
150 lb. ANSI raised face flanges are available on the 316 stainless steel units only.
3 Housing head has mounting bosses which accept self-tapping screws.
4 Painted exterior for cast iron.
Dimensional Data (nominal)
| Model | Connecton Size 1⁄2 in. |
3⁄4 in. |
1 in. |
Flow Rate5 lpm (gpm) |
Dimensions cm (in) A |
B |
Sealing Distance cm (in.) |
Weight kg (lb) |
| LMOSS10 | X | X | to 37.9 (10) | 34.3 (13.5) | 12.1(4.75) | 24.8 - 25.6 (9.75 - 10.06) | 3.1 (6.75) | |
| LMOSS20 | X | X | to 75.7 (20) | 59.7 (23.5) | 12.1(4.75) | 50.2 - 51.1 (19.75 - 20.13) | 4.1 (9) | |
| LMOSS10S | X | X | X | to 37.9 (10) | 34.3 (13.5) | 12.1(4.75) | 24.8 - 25.6 (9.75 - 10.06) | 3.1 (6.75) |
| LMOSS20S | X | X | to 75.7 (20) | 59.7 (23.5) | 12.1(4.75) | 74.9 - 76.7 (19.5 - 20.125) | 4.1 (9) | |
| LMOSS30S | X | X | to 113.6 (30) | 85.1 (33.5) | 12.1(4.75) | 49.5 - 51.1 (29.5 - 30.19) | 5.1 (11.25) | |
5 Dependent upon cartridge selection, fluid viscosity and allowable pressure drop at various flow rates. Refer to cartridge nomograph to determine initial pressure drop of filter cartridge.

Housing Differential Pressure vs. Liquid Flow Rate

Unit Conversion: 1 bar = 100 kPa
For liquids other than water, multiply differential pressure by specific gravity.

Table 1
| Code | Cartridge lengths (cm/in.) |
| 42 | 10.2/4 |
| 10 | 25.4/10 |
| 20 | 50.8/20 |
| 30 | 76.2/30 |
Table 2
| Code | Materials of construction |
| Blank | Cast iron and carbon steel |
| S | 316 stainless steel |
Table 3
| Code | Connection sizes (in.) |
| 1⁄2 | 1⁄2 |
| 3⁄4 | 3⁄4 |
| 1 | 1 |
Table 4
| Code | Connection styles |
| Blank | NPT |
| F | Flange6 |
English