앰풀 개봉과 유리 오염
앰풀을 열면 환자가 유리에 오염될 수 있다는 것을 알고 계셨습니까?
2021년 1월 6일
환자 치료에 사용되는 약물이 들어 있는 유리 앰풀은 흔히 사용되는 앰풀이며 이는 의료 종사자, 특히 간호사에게 발생하는 업무상 상해의 가장 일반적인 원인입니다.1
Glass particles have also been shown to contaminate the ampoules during ampoule breaking, these can then be transferred to the patient by injection.2,3,4 Injected glass particles can travel through the blood vessels and may cause several harmful side effects, including pulmonary thrombi, micro-emboli,5,6 infusion phlebitis, end-organ granuloma formation and inflammation.7,8,9,10,11
IV 인라인 필터는 유리 입자가 들어 있을 수 있는 미립자를 제거할 수 있는 장점을 제공합니다.11
동영상을 시청하여 앰풀을 열었을 때 유리 입자가 어떻게 이동하는지 알아보십시오!
일회용 유리 앰풀을 개봉하는 느린 동작
References
- Chiannilkulchai N. & Kejkornkaew S. (2020). A Comparative Study of Ampoule Breaking and Resultant Injury among Registered Nurses. Pacific Rim Int J Nurs Res; 24(1): 89-101.
- Joo G.E., Sohng K.Y. and Park M.Y. (2016). The effect of different methods of intravenous injection on glass particle contamination from ampules. Springer Plus; 5 (15): 1-8.
- Caudron E., Tfayli A., Monnier C. et al. (2011) Identification of hematite particles in sealed glass containers for pharmaceutical uses by Raman microspectroscopy. J Pharm Biomed Anal; 54(4): 866–868.
- Preston S.T. and Hegadoren K. (2004). Glass contamination in parenterally administered medication. Journal of Advanced Nursing; 48(3): 266-270.
- Stebbens W.E. & Florey H.W. (1960). The behavior of intravenously injected particles observed in chambers in rabbits’ ears. Quarterly Journal of Experimental Physiology; 45: 252-264
- Lockhart J.D. (1966) The medical significance of particulate matter in large volume parenteral solutions. Safety of large volume parenteral solutions. National Symposium Proceedings, FDA, Washington, DC p. 28.
- Garvan J.M. & Gunner B.W. (1964). The harmful effects of particles in intravenous fluids. Medical Journal of Australia; 2: 1-6.
- Michaels L. & Poole R.W. (1970). Injection granuloma of the buttock. Canadian Medical Association Journal; 102: 626–628.
- Furgang F.A. (1974). Glass particles in ampoules. Anesthesiology; 41(5): 525.
- Belanger-Annable M.C. (1985). Long acting neuroleptics: technique for intramuscular injection. Canadian Nurse; 81(8): 41-44.
- Shaw N.J. and Lyall E.G.H. (1985). Hazards of glass ampoules. British Medical Journal; 291 (6505): 1390.
- Perez M., Décaudin B., Chahla W.A et al. (2018). Effectiveness of in-Line Filters to Completely Remove Particulate Contamination During a Pediatric Multidrug Infusion Protocol. Sci Rep; 8 (7714): 1-8.