Particle Removal at Elevated Flow Rates
Ultipleat High Flow filter elements are designed for high particle removal efficiency in high flow rate food and beverage applications. The Ultipleat High Flow filter elements utilize Profile UP media with unique, laid-over pleat geometry. The Ultipleat High Flow element is a large diameter, single open ended, pleated cartridge with an inside to outside flow pattern and a core-free construction.
The filter’s unique, laid-over pleat geometry, combined with its large diameter, means fewer elements are required for a given flow rate than standard cartridges diameter. Filter vessels are correspondingly smaller, resulting in lower capital and installation costs, as well as reduced operating costs.
|
| Fixed fiber matrix with no adhesives or surfactants |
- Consistent filtrate quality
- Highly stable structure
- Higher product yields
- Process reliability
|
| Pleated (laid-over pleat geometry) media in a large diameter cartridge format |
- Lower capital and installation costs*
- Reduced installation footprint*
- 30% lower operating costs*
- Longer service life
- 10% water savings*
|
| Inside to outside flow configuration |
Protects filtrate from recontamination by trapping particulates inside the cartridge |
|
*Typical compared to standard cartridges used in test comparison.
Recommended for fluid applications with inside to out flow rates of >20 m
3/h (100 USgpm). Outside to in flow is not recommended.
Please contact your Pall representative for product recommendations more suitable to lower flow rates.
Food Contact Compliance
Ultipleat Filter Element Construction, Showing Uniform Flow Distribution
Materials of Construction
- Filter Medium: Polypropylene
- Support Mesh and Outer Wrap: Polypropylene
- End Caps and Handle: Polypropylene (10% glass fiber reinforced)
- O-ring Seal: Ethylene Propylene Rubber
Operating Characteristics in Compatible Fluids1
- Maximum Differential Pressure: 3.45 bard (50 psid) (forward pressure)
- Max. Operating Temperature2: 82 °C (180 °F)
Typical Flow Rates3
1Compatible fluids are defined as those which do not swell, soften or attack any of the filter components.
2Not recommended where the temperature is cycled more than 10 °C (50 °F).
3Typical initial clean media differential pressure (Δp) per 1016 mm (40”) and 1524 mm (60”) cartridge for water at 20 °C (68 °F); viscosity 1 centipoise. For assistance in filter assembly sizing and housing selection, especially for fluids with a viscosity > 1 centipoise, contact your Pall Representative.
Quality
- Cartridges produced in a controlled environment
- Manufactured according to ISO 9001:2008 certified Quality Management System
This information is a guide to the part number structure and possible options. For availability of specific options and housing details, please
contact Pall.
Example Part Number: HFU 6
40 UY020 JUW (See bold references in tables below.)
Element Part Number: HFU 6 <Nominal Length Code from Table 1> <Liquid Removal Rating Code from Table 2> JUW
Table 1 - Nominal Length
|
| 40 |
1016 mm (40 in.) |
| 60 |
1524 mm (60 in.) |
|
Table 2 - Liquid Removal Rating4
|
| UY020 |
|
2.0 |
| UY045 |
4.5 |
2.5 |
| UY100 |
10 |
6.5 |
| UY200 |
>25 |
17.9 |
| UY400 |
50 |
|
|
4The UY400 grade was qualified by maximum spherical particle retention test.