Marksman™ PFT Series Filter Elements
High Capacity Pleated
Polypropylene Filter Elements
- New, larger cartridge geometry
- High flow capacity
- Poly-Fine® II proprietary media for highly consistent filtration
- Inside-out flow traps contaminant inside the element
- Available to fit most Size 1 and Size 2 bag housings with no hardware changes
- Available in 101.6 cm (40 in) for use in unique 101.6 cm (40 in) Marksman housings
- Unique sealing device adjusts to fit in most bag filter housings
- High surface area for long service life
- All polypropylene construction
- Wide chemical compatibility
- Short length option to accommodate shorter baskets
Filter Grades
- 1, 3, 5, 10, 20, 40, 70, 90, 150 micron (μm)
Maximum Operating Differential Pressure
- To 5.2 bard @ 20 °C (75 psid @ 68 °F)
- To 2.4 bard @ 74 °C (35 psid @ 165 °F)
Recommended Change-out Differential Pressure1
- 2.4 bard @ up to 54 °C (35 psid @ up to 130 °F)
Food and Water Contact Use
- Please contact Pall Corporation to verify that the product conforms to your national legislation and/or regional regulatory requirements for water and food contact use.
Purity
- Cartridges do not use surfactants, binders, and adhesives.
Sanitization
- Contact Pall Corporation for assistance.
Materials of Construction
- Filter media: Polypropylene
- Hardware: Polypropylene
- Support material: Polypropylene
- Gaskets: EPDM, fluorocarbon elastomer, nitrile
- Sealing: Thermal bond
Dimensions (Nominal)
- Outside flange diameter: Three diameters are available. Contact Pall for information on sizes.
- Outside filter diameter: 15.2 cm (6 in.)
- Lengths:
Size 1 - Standard, Short
Size 2 - Standard, Short, Extra Short
Size 4 - 101.6 cm (40 in)
Particle Removal Ratings2 (μm)
| Cartridge Designation | 90% Efficiency | >99.9% Efficiency |
| PFTM 1 | 1 | - |
| PFTM 3 | 2 | - |
| PFTM 5 | - | 5 |
| PFTM 10 | - | 9 |
| PFTM 20 | - | 15 |
| PFTM 40 | 20 | - |
| PFTM 70 | - | 70 |
| PFTM 90 | 57 | - |
| PFTM 150 | - | 145 |
Typical Flow
| mbard/lpm (psid/gpm) Water @ 20°C (68°F) | |||||
| Filter Grade | Size 1 | Size 2 | 40 in | Size 1 (short) | Size 2 (short) |
| 1 | 0.838 (0.046) |
0.364 (0.020) |
0.273 (0.015) |
0.765 (0.042) |
0.328 (0.018) |
| 3 | 0.346 (0.019) |
0.164 (0.008) |
0.109 (0.006) |
0.310 (0.017) |
0.128 (0.007) |
| 5 | 0.109 (0.006) |
0.054 (0.003) |
0.018 (0.001) |
0.109 (0.006) |
0.054 (0.003) |
| 10 | 0.054 (0.003) |
0.018 (0.001) |
0.018 (0.001) |
0.054 (0.003) |
0.018 (0.001) |
| 20 | 0.036 (0.002) |
0.018 (0.001) |
0.018 (0.001) |
0.036 (0.002) |
0.018 (0.001) |
| 40 | 0.018 (0.001) |
0.018 (0.001) |
0.018 (0.001) |
0.036 (0.002) |
0.018 (0.001) |
| 70 | 0.018 (0.001) |
0.018 (0.001) |
0.018 (0.001) |
0.018 (0.001) |
0.018 (0.001) |
| 90 | 0.018 (0.001) |
0.018 (0.001) |
0.018 (0.001) |
0.018 (0.001) |
0.018 (0.001) |
| 150 | 0.018 (0.001) |
0.018 (0.001) |
0.018 (0.001) |
0.018 (0.001) |
0.018 (0.001) |
1Provided that the maximum differential pressure is not exceeded based on temperature limits defined above.
2Marksman PFT series filter cartridge retention ratings are based on Pall’s Dynamic Efficiency test protocol. This single pass, destructive challenge test is based on ASTM F-795 test procedures for determining the performance of a filter medium. Fine test dust is used as the test contaminant for filters in the 1 to 20 micron range. Coarse test dust is used for micron ratings above 20 micron. Additional information can be obtained by contacting Pall Corporation. NOTE: PFTM grade designations for 1, 3, 40, and 90 based on Beta 10 values, and all other grade designations are based on Beta 1000 values.
This information is a guide to the part number structure and possible options. For availability of specific options and housing details, please contact Pall.
Example Part Number: PFTM S 3 - 1 U V - PF B ( See bold references in tables below)
3Size 2 (only)
Part Number: PFTM < Length Code from Table 1 > < Length Code from Table 2 > - < Cartridge Code from Table 3 > U < Gasket Code from Table 4 > - < Configuration Code from Table 5 > < Flange/Gasket Code from Table 6 >
Table 1 - Short Length Option
| Code | Short Length Option |
| Blank | Standard |
| S | Short |
| XS | Extra short 3, 4 |
Table 2 - Filter Grades (µm)
| Code | Filter Grades (μm) |
| 1 | 1 |
| 3 | 3 |
| 5 | 5 |
| 10 | 10 |
| 20 | 20 |
| 40 | 40 |
| 70 | 70 |
| 90 | 90 |
| 150 | 150 |
Table 3 - Cartridge Lengths Nominal
| Code | Cartridge Lengths Nominal |
| 1 | Size 1 bag |
| 2 | Size 2 bag |
| 4 | 101.6 cm |
Table 4 - Gasket Materials
| Code | Gasket Materials |
| Blank | For NF version |
| N | Nitrile |
| E | EPDM (peroxide cured) |
| V | Fluorocarbon elastomer |
Table 5 - End Configuration
| Code | End Configurations |
| PF | Plastic self-adjusting flange |
| SF | Stainless steel self-adjusting flange (required for temperatures >43°C/110°F) |
| NF | No flange (for use with reusable SS flange) |
Table 6 - Flange/Gasket styles5
| Code | Flange/Gasket Styles5 |
| A6 | Rosedale7, Strainrite, Krystil Klear8, Pall |
| B | GAF9, FSI10 side entry |
| C | FSI over the top, Hayward11 over the top |